Search results for "width [beam]"
showing 10 items of 168 documents
High Resolution Spectroscopy of 4U 1728-34 from a Simultaneous Chandra-RXTE Observation
2004
We report on a simultaneous Chandra and RossiXTE observation of the LMXB atoll bursting source 4U 1728-34 performed on 2002 March 3-5. We fitted the 1.2-35 keV continuum spectrum with a blackbody plus a Comptonized component. An overabundance of Si by a factor of ~2 with respect to Solar abundance is required for a satisfactory fit. Large residuals at 6-10 keV can be fitted by a broad (FWHM ~ 1.6 keV) Gaussian emission line, or, alternatively, by absorption edges associated with Fe I and Fe XXV at ~7.1 keV and ~9 keV, respectively. In this interpretation, we find no evidence of a broad, or narrow Fe Kalpha line, between 6 and 7 keV. We tested our alternative modeling of the iron Kalpha regi…
A three domain controller for a high frequency high power four quadrant power converter for superconducting magnets
2002
The paper describes the implementation of a controller that orchestrates the functioning of three subsystems that implement a high energy converter (/spl plusmn/1500 A, /spl plusmn/15 V) that supplies a superconducting magnet to be used in particle accelerators. The performance of the whole system, in accordance to specifications, is documented with experimental results.
A large proportional drift chamber with two-dimensional read-out
1976
Abstract The construction and performance of a large drift chamber are described, which has a sensitive area of 5 m2 and an average chamber thickness of 0.55 × 10−3 radiation lengths. Simultaneous sense wire- and high voltage read-out gives a good time correlation with ajitter of 2.0 ns fwhm. Measurements with a collimated radioactive α-sources resulted in a time resolution of 4.3 ns fwhm corresponding to a space resolution of 0.20 mm fwhm at the sense wire. The space resolution at the high voltage plane is about 25 mm fwhm.
A/V ratio as predicted by full width at half maximum and by blood vessel tracking in presence of ocular aberrations
2011
Aberrations impact A/V ratio calculated from full width at half maximum. We investigated whether aberrations affect A/V ratio calculated by tracking the vessels. Aberrations changed the A/V ratio. We conclude that aberrations impact A/V ratio.
HIGH-RESOLUTION FOURIER TRANSFORM SPECTROSCOPY OF LANTHANUM IN Ar DISCHARGE IN THE NEAR-INFRARED
2013
A high-resolution spectrum of lanthanum has been recorded by a Fourier Transform spectrometer in the wavelength range from 833 nm to 1666 nm (6000 cm{sup –1} to 12,000 cm{sup –1}) using as light source a hollow cathode lamp operated with argon as the discharge carrier gas. In total, 2386 spectral lines were detected in this region, of which 555 lines could be classified as La I transitions and 10 lines as La II transitions. All La II transitions and 534 of these La I transitions were classified for the first time, and 6 of the La II transitions and 433 of the classified La I transitions appear to be new lines, which could not be found in the literature. The corresponding energy level data o…
Analysis of the infrared Fourier transform spectrum of the Dyad of 116SnH4
1990
Abstract The FTIR spectrum of monoisotopic 116SnH4 has been recorded with the Bruker 120 HR interferometer at Giessen, West Germany, in the ν 2 ν 4 range extending from 600 to 850 cm−1. The resolution (FWHM) was 2.1 × 10−3 cm−1. The Dyad ν 2 ν 4 (0100, 0001) was analyzed using a sixth-order Hamiltonian. The analysis of infrared transitions enabled us to determine 10 ground state parameters, 9 ν2 parameters, 17 ν4 parameters, and 18 interaction parameters. Of 3800 calculated transitions assigned to observed lines, 1183 unblended lines have been selected for the data refinement. For J ≤ 19, the value of the standard deviation is of the order of magnitude of the estimated experimental accuracy…
Grating compensated dispersion-managed systems incorporating nonlinear optical loop mirrors
2006
In this work, we investigate the use of nonlinear optical loop mirrors (NOLMs) in DM fiber systems compensated by CFGs with GDR by launching a 128-bit Gaussian-shaped pseudo-random bit sequence having pulse width of 5 ps for simulating a 40 Gb/s system. The dispersion map contains a fiber segment of length 10.3 km and a CFG with dispersion of -15.6 ps/nm. We consider a lossless grating and the GDR is modeled by a sinusoidal function for simplicity. We have shown that the use of NOLMs can substantially improve the transmission performance in a grating-compensated DM fiber system even with presence of amplifier noise and random variations of GDR, parameters in CFGs along the propagation dista…
Efficient control of the energy exchange due to the Manakov vector-soliton collision
2003
By examining the concept of energy exchange among the orthogonally polarized components of each of two colliding (Manakov-like) vector solitons it is observed that a maximum or an efficient energy-exchange process is possible only for an appropriate choice of the initial physical parameters (namely, frequency separation, polarizations, time delay, and pulse-width separation between the colliding solitons) for which L(W) (walk-off length) >>L(NL) (nonlinear length). However, in this case only, the amount of energy-exchange can be considerably increased or decreased by appropriately changing the phases of colliding solitons without altering the walk-off length and the initial energy distribut…
A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra
2004
Abstract A two-detector spectrometer for measurements of Doppler broadened positron annihilation spectra has been constructed and tested. The energy difference of the annihilation quanta is measured in the analogue, not in the digital manner. The peak to background ratio in the measured spectra is of the order of 10 6 , the FWHM representing the energy resolution, equals to 1.1 keV , thus enabling the very subtle physical effects to be revealed. Some information on electronic structure of the investigated 3-d metals (Ti, V, Cr, Fe, Ni, Cu and Zn) has been determined using this spectrometer. It has been shown that the apparatus permits to detect the impurity-vacancy pairs in dilute nickel al…
Improving the Performance of Quasi-Hemispherical CdZnTe Detectors Using Infrared Stimulation
2012
The influence of monochromatic optical stimulation with wavelengths from 400 to 1100 nm on the characteristics of CdZnTe quasi-hemispherical detectors was studied. It was found that illumination with infrared (IR) light with wavelengths of 870-900 nm close to the absorption edge of the CdZnTe significantly improves the performance of the detector at room temperature. Improvement can be achieved with low-intensity IR illumination at 1-300 μW depending on the chosen wavelength of illumination. Higher intensity illumination was observed to lead to the degradation of the detector's spectrometric characteristics. IR radiation was noted to influence the detector's sensitivity, changing the equili…